Triup 300mA X-Ray Machine (TR-300A)

Applications

Ideal for General Radiography, Chest X-Ray, Abdominal Imaging, Orthopedic Imaging, and routine diagnostic examinations in hospitals, clinics, and community health centers.

Technical Specifications (Summary)

Component Specification
Model TR-300A
Power Supply 380V / 220V ±10%, 50Hz ±0.5Hz
High-Voltage Generator Single-phase full-wave rectification
Max DC Output: 125kV / 300mA
Radiographic Voltage 50kV ~ 125kV (infinitely variable)
Radiographic Current Small Focus: 50mA, 100mA
Big Focus: 100mA, 200mA, 300mA
Exposure Time 0.05s ~ 6.3s (20 grades, R10 coefficient)
X-Ray Tube Model: XD51-20.40/125
Rotary Anode / Dual Focus: 1x1mm (Small), 2x2mm (Big)
Radiographic Table Table Dimensions: 2060mm x 730mm x 700mm
Table Movement: 800mm (Longitudinal) / 230mm (Transverse)
Tube Stand Movement Vertical Travel: 1140mm ~ 1800mm
Rotation around Cross Arm: ±180°
Grid Grid Density: N28 / Grid Ratio: R8 / Focus Distance: 1000mm
Max Cassette Size 14″ x 17″ (356mm x 432mm)
Get Price Quote
0 People watching this product now!
Description

Short Description

The TR-300A is a reliable, single-tube, single-bed diagnostic X-ray system designed for general radiography. Featuring a rotary anode X-ray tube, single-phase full-wave rectification, and intuitive digital controls, it delivers consistent performance for routine examinations in hospitals and clinics.

Full Description

Dependable Performance for Routine Diagnostics

The TR-300A is a versatile and durable stationary X-ray system engineered to meet the daily demands of radiology departments. With its robust 300mA high-voltage generator, precise digital timing, and flexible positioning, it provides accurate and reliable imaging for a wide range of general radiographic applications.

Key Features & Benefits

  • Powerful 300mA Generator: Single-phase full-wave rectification high-voltage generator with max DC output of 125kV and 300mA, ensuring reliable performance for standard radiographic examinations.
  • Rotary Anode X-Ray Tube: Equipped with a dual-focus X-ray tube (small focus 1x1mm, big focus 2x2mm) for optimal image detail and tube longevity.
  • Flexible Power Supply: Operates on 380V or 220V power (with adjustable range ±10%), offering installation flexibility for various facility requirements.
  • Precise Digital Timing: Digital circuit timer with 20 exposure time grades (0.05-6.3s) according to R10 priority coefficient, ensuring exact time control for consistent results.
  • Intuitive Control System: Features infinitely variable control for power voltage and kilovolt (kV), with subsection, grading, and interlock protection for safe and easy operation.
  • Stable Filament Control: Equipped with a manostat for the X-ray tube filament and space charge compensation, ensuring stable tube current.
  • Large Movable Table: The radiographic bed (2060mm x 730mm) offers longitudinal (800mm) and transverse (230mm) movement for easy patient positioning.
  • Versatile Tube Stand: The X-ray tube assembly provides extensive positioning flexibility with ±180° rotation around the cross arm and a wide range of vertical travel (1140mm-1800mm).

Integrated Design: The radiographic bed, pillar, and vibrating ray-filter form a single, stable unit without top or bottom tracks, simplifying installation and floor maintenance.