Technical Specifications (Summary)
| Component | Specification |
| Model | TR-300A |
| Power Supply | 380V / 220V ±10%, 50Hz ±0.5Hz |
| High-Voltage Generator | Single-phase full-wave rectification Max DC Output: 125kV / 300mA |
| Radiographic Voltage | 50kV ~ 125kV (infinitely variable) |
| Radiographic Current | Small Focus: 50mA, 100mA Big Focus: 100mA, 200mA, 300mA |
| Exposure Time | 0.05s ~ 6.3s (20 grades, R10 coefficient) |
| X-Ray Tube | Model: XD51-20.40/125 Rotary Anode / Dual Focus: 1x1mm (Small), 2x2mm (Big) |
| Radiographic Table | Table Dimensions: 2060mm x 730mm x 700mm Table Movement: 800mm (Longitudinal) / 230mm (Transverse) |
| Tube Stand Movement | Vertical Travel: 1140mm ~ 1800mm Rotation around Cross Arm: ±180° |
| Grid | Grid Density: N28 / Grid Ratio: R8 / Focus Distance: 1000mm |
| Max Cassette Size | 14″ x 17″ (356mm x 432mm) |
Short Description
The TR-300A is a reliable, single-tube, single-bed diagnostic X-ray system designed for general radiography. Featuring a rotary anode X-ray tube, single-phase full-wave rectification, and intuitive digital controls, it delivers consistent performance for routine examinations in hospitals and clinics.
Full Description
Dependable Performance for Routine Diagnostics
The TR-300A is a versatile and durable stationary X-ray system engineered to meet the daily demands of radiology departments. With its robust 300mA high-voltage generator, precise digital timing, and flexible positioning, it provides accurate and reliable imaging for a wide range of general radiographic applications.
Key Features & Benefits
- Powerful 300mA Generator: Single-phase full-wave rectification high-voltage generator with max DC output of 125kV and 300mA, ensuring reliable performance for standard radiographic examinations.
- Rotary Anode X-Ray Tube: Equipped with a dual-focus X-ray tube (small focus 1x1mm, big focus 2x2mm) for optimal image detail and tube longevity.
- Flexible Power Supply: Operates on 380V or 220V power (with adjustable range ±10%), offering installation flexibility for various facility requirements.
- Precise Digital Timing: Digital circuit timer with 20 exposure time grades (0.05-6.3s) according to R10 priority coefficient, ensuring exact time control for consistent results.
- Intuitive Control System: Features infinitely variable control for power voltage and kilovolt (kV), with subsection, grading, and interlock protection for safe and easy operation.
- Stable Filament Control: Equipped with a manostat for the X-ray tube filament and space charge compensation, ensuring stable tube current.
- Large Movable Table: The radiographic bed (2060mm x 730mm) offers longitudinal (800mm) and transverse (230mm) movement for easy patient positioning.
- Versatile Tube Stand: The X-ray tube assembly provides extensive positioning flexibility with ±180° rotation around the cross arm and a wide range of vertical travel (1140mm-1800mm).
Integrated Design: The radiographic bed, pillar, and vibrating ray-filter form a single, stable unit without top or bottom tracks, simplifying installation and floor maintenance.